Echelon IzoT NodeBuilder Instrukcja Użytkownika Strona 220

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 291
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 219
FT 5000
SCL
SDA_CS1~
RST~
Aardvark
SCL
SDA
GND
Serial
EEPROM
Device
GND
GND
45
43
28
1
3
2
10
SDA
SCL
GND
VCC
R1
4.99k
VCC
R2
4.99k
Serial EEPROM-Aardvark I
2
C Connection
(Direct Connection)
Note: Pins 2 and 10 on the Aardvark are both connected to ground inside the Aardvark. As a result,
when the Aardvark is connected to the device board, it finds a reference ground at pin 10 and it takes
the RST~ line to ground on pin 2 at the same time. This means that once the Aardvark connection is
removed, the RST~ line is released and the 5000 or 6000 Series chip resumes normal operation.
206 Building and Downloading Device Applications